Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 104
Filter
1.
HAYATI Journal of Biosciences ; 30(4):621-631, 2023.
Article in English | Scopus | ID: covidwho-20241710

ABSTRACT

Colorimetric RT-LAMP Assay is a diagnostic method that has attracted much attention because of its rapidity, simplicity, and accuracy compared to other disease diagnosis methods. Despite having many advantages, the RT-LAMP Colorimetric Assay has disadvantages, especially for kits that use phenol red as an indicator. The disadvantage derives from the input RNA/DNA samples containing high buffer levels, which causes no color change and false-negative results. This study aimed to develop and optimize the colorimetric RT-LAMP method on high-buffered SARS-CoV-2 RNA samples. We found that a temperature of 69°C for 50 minutes with the addition of post-treatment in the form of heating at 80°C for 10 minutes is an optimal condition for high-buffered SARS-CoV-2 samples. The condition proved effective in changing the result's color from red (negative) to yellow (positive). We also classified the analysis results based on the correlation between the Cycle threshold (Ct) value of SARS-CoV-2 viruses and the Optical Density (OD) value, which was quantified using a spectrophotometer at 415 nm (with a correlation value of-0.9084), where yellow color indicated Ct below 20, amber color indicated Ct between 20 and 30, orange color indicated Ct between 30 and 35, and red indicated Ct more than 35 (negative). In conclusion, this study successfully detects the SARS-CoV-2 virus in high-buffered samples using Phenol Red Colorimetric RT-LAMP Assay, with a sensitivity of 85% for Ct Cutoff 40. © 2023, Bogor Agricultural University. All rights reserved.

2.
Appl Biol Chem ; 66(1): 13, 2023.
Article in English | MEDLINE | ID: covidwho-2309153

ABSTRACT

CRISPR-Cas systems have been widely used in genome editing and transcriptional regulation. Recently, CRISPR-Cas effectors are adopted for biosensor construction due to its adjustable properties, such as simplicity of design, easy operation, collateral cleavage activity, and high biocompatibility. Aptamers' excellent sensitivity, specificity, in vitro synthesis, base-pairing, labeling, modification, and programmability has made them an attractive molecular recognition element for inclusion in CRISPR-Cas systems. Here, we review current advances in aptamer-based CRISPR-Cas sensors. We briefly discuss aptamers and the knowledge of Cas effector proteins, crRNA, reporter probes, analytes, and applications of target-specific aptamers. Next, we provide fabrication strategies, molecular binding, and detection using fluorescence, electrochemical, colorimetric, nanomaterials, Rayleigh, and Raman scattering. The application of CRISPR-Cas systems in aptamer-based sensing of a wide range of biomarkers (disease and pathogens) and toxic contaminants is growing. This review provides an update and offers novel insights into developing CRISPR-Cas-based sensors using ssDNA aptamers with high efficiency and specificity for point-of-care setting diagnostics.

3.
Chinese Journal of Analytical Chemistry ; 51(7), 2023.
Article in English | Scopus | ID: covidwho-2295202

ABSTRACT

Visual detection of nucleic acids is important to diagnose the serious acute infectious diseases such as coronavirus disease 2019 (COVID-19). During this pandemic, reliable visual detection kits have been in high demand for screening and prevention of the virus. While developing these visual detection kits, a real-time monitoring platform is usually applied to study the amplification and detection processes of nucleic acids and optimize the detecting conditions. Herein, we developed a real-time monitoring platform of colorimetric loop-mediated isothermal amplification (LAMP) to investigate the amplification and detection processes of nucleic acids. Using this platform, we could obtain the real-time amplification curves, and optimize the reaction temperature, color change, and detection time. Based on the optimized conditions, a visual detection kit for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was successfully developed with a sensitivity of 102 copies µL−1 in 12 min. This real-time monitoring platform has advantages of simple construction, steady performance, high sensitivity, and outstanding anti-pollution capability, and could replace the traditional colorimetric methods by photographing and reading values. This platform would accelerate the development of visual detection kits for colorimetric LAMP, help to explore the amplification and transcription of nucleic acids, and provide support for the prevention of emerging biological threats. © 2023

4.
ACS Appl Mater Interfaces ; 15(16): 20483-20494, 2023 Apr 26.
Article in English | MEDLINE | ID: covidwho-2297232

ABSTRACT

Surface ligands play a critical role in controlling and defining the properties of colloidal nanocrystals. These aspects have been exploited to design nanoparticle aggregation-based colorimetric sensors. Here, we coated 13-nm gold nanoparticles (AuNPs) with a large library of ligands (e.g., from labile monodentate monomers to multicoordinating macromolecules) and evaluated their aggregation propensity in the presence of three peptides containing charged, thiolate, or aromatic amino acids. Our results show that AuNPs coated with the polyphenols and sulfonated phosphine ligands were good choices for electrostatic-based aggregation. AuNPs capped with citrate and labile-binding polymers worked well for dithiol-bridging and π-π stacking-induced aggregation. In the example of electrostatic-based assays, we stress that good sensing performance requires aggregating peptides of low charge valence paired with charged NPs with weak stability and vice versa. We then present a modular peptide containing versatile aggregating residues to agglomerate a variety of ligated AuNPs for colorimetric detection of the coronavirus main protease. Enzymatic cleavage liberates the peptide segment, which in turn triggers NP agglomeration and thus rapid color changes in <10 min. The protease detection limit is 2.5 nM.


Subject(s)
Colorimetry , Metal Nanoparticles , Colorimetry/methods , Gold/chemistry , Metal Nanoparticles/chemistry , Polymers , Ligands
5.
ACS Sens ; 8(4): 1422-1430, 2023 04 28.
Article in English | MEDLINE | ID: covidwho-2303906

ABSTRACT

Here, quercetin-mediated silver nanoparticle (AgNP) formation combined with loop-mediated isothermal amplification (LAMP) was introduced to colorimetrically detect two major infectious pathogens, SARS-CoV-2 and Enterococcus faecium, using a foldable PMMA microdevice. The nitrogenous bases of LAMP amplicons can readily form a complex with Ag+ ions, and the catechol moiety in quercetin, which acted as a reducing agent, could be chelated with Ag+ ions, resulting in the easy electron transfer from the oxidant to the reductant and producing brown-colored AgNPs within 5 min. The introduced method exhibited higher sensitivity than agarose gel electrophoresis due to more active redox centers in quercetin. The detection limit was attained at 101 copies µL-1 and 101 CFU mL-1 for SARS-CoV-2 RNA and E. faecium, respectively. A foldable microdevice made of two pieces of PMMA that fully integrates DNA extraction, amplification, and detection processes was fabricated to establish practical applicability. On one PMMA, DNA extraction was performed in a reaction chamber inserted with an FTA card, and then LAMP reagents were added for amplification. Silver nitrate was added to the reaction chamber after LAMP. On the other PMMA, quercetin-soaked paper discs loaded in the detection chamber were folded toward the reaction chamber for colorimetric detection. An intense brown color was produced within 5 min when heated at 65 °C. The introduced colorimetric assay, which is highly favorable for laboratory and on-site applications, could be a valuable alternative to conventional methods for detecting infectious diseases, given its unique principle, simplicity, and naked-eye detection.


Subject(s)
COVID-19 , Communicable Diseases , Metal Nanoparticles , Humans , Colorimetry/methods , Quercetin , Polymethyl Methacrylate , RNA, Viral , SARS-CoV-2 , Silver , DNA
6.
Anal Chim Acta ; 1257: 341167, 2023 May 29.
Article in English | MEDLINE | ID: covidwho-2302415

ABSTRACT

The world is in a long pandemic period caused by the SARS-CoV-2 virus and massive diagnostic tests to assist efforts to control the spread of the disease and also to avoid new coronavirus variants are still needed. Herein, we propose a simple and accurate saliva-based colorimetric test for the diagnosis of COVID-19. Magnetic beads (MBs) modified with a sequence of single-strand DNA (ssDNA) complementary to the N gene of the SARS-CoV-2 RNA were developed and used for magnetic capture and separation from a complex saliva sample. A second biotinylated ssDNA sequence was applied, and the colorimetric detection was carried out by adding streptavidin-horseradish peroxidase conjugate, H2O2, and tetramethylbenzidine (TMB) as chromogenic substrate. The test does not require viral RNA isolation, transcription, or amplification steps and can be performed at room temperature. The molecular assay test can be run using 96-well microplates, allowing the diagnosis of a large number of samples in 90 min. A simple support for magnets was designed and constructed using a 3D printer that allows the magnetic separations directly in the 96-well microplate. The colorimetric test showed an excellent ability to discriminate between healthy individuals and patients infected with SARS-CoV-2, with 92% and 100% of clinical sensitivity and specificity, respectively. This performance was similar to that achieved using the gold standard RT-PCR technique. The proposed genomagnetic assay offers an opportunity to greatly increase population testing, contribute to controlling the spread of the virus, and improve health equity in testing for COVID-19.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2/genetics , COVID-19 Testing , RNA, Viral/genetics , Colorimetry/methods , Sensitivity and Specificity , Nucleic Acid Amplification Techniques/methods
7.
Diagnostics (Basel) ; 13(7)2023 Apr 06.
Article in English | MEDLINE | ID: covidwho-2302188

ABSTRACT

Quick and reliable mass testing of infected people is an effective tool for the contingency of SARS-CoV-2. During the COVID-19 pandemic, Point-of-Care (POC) tests using Loop-Mediated Isothermal Amplification (LAMP) arose as a useful diagnostic tool. LAMP tests are a robust and fast alternative to Polymerase Chain Reaction (PCR), and their isothermal property allows easy incorporation into POC platforms. The main drawback of using colorimetric LAMP is the reported short-term stability of the pre-mixed reagents, as well as the relatively high rate of false-positive results. Also, low-magnitude amplification can produce a subtle color change, making it difficult to discern a positive reaction. This paper presents Hilab Molecular, a portable device that uses the Internet of Things and Artificial Intelligence to pre-analyze colorimetric data. In addition, we established manufacturing procedures to increase the stability of colorimetric RT-LAMP tests. We show that ready-to-use reactions can be stored for up to 120 days at -20 °C. Furthermore, we validated both the Hilab Molecular device and the Hilab RT-LAMP test for SARS-CoV-2 using 581 patient samples without any purification steps. We achieved a sensitivity of 92.93% and specificity of 99.42% (samples with CT ≤ 30) when compared to RT-qPCR.

8.
ACS Sustainable Chemistry and Engineering ; 11(6):2079-2088, 2023.
Article in English | Scopus | ID: covidwho-2281786

ABSTRACT

Here, we developed a copper sulfate (CuSO4)-initiated diphenylamine (DPA)-based colorimetric strategy coupled with loop-mediated isothermal amplification (LAMP) for rapid detection of two critical contagious pathogens, SARS-CoV-2 and Enterococcus faecium. To detect the DNA, acid hydrolysis of LAMP amplicons was executed, enabling the development of a blue color. In the LAMP amplicons, the bond between the purines and deoxyribose is extremely labile. It can be broken using 70% sulfuric acid followed by phosphate group elimination, which generates a highly active keto aldehyde group. CuSO4 plays an imperative role inducing DPA to rapidly react with the keto aldehyde group, producing an intense blue color within 5 min. Moreover, low quantities such as 103 copies μL-1 of SARS-CoV-2 RNA and 102 CFU mL-1 of E. faecium were successfully detected, revealing the advantages of the introduced method. To confirm practical applicability, multiplex detection of pathogens was performed using a foldable microdevice comprising reaction and detection zones. Various reactions such as DNA extraction, LAMP, and acid hydrolysis occurred in the reaction zone. Then, colorimetric reagents (DPA, CuSO4, and ethylene glycol) contained in the detection zone were mixed with the keto aldehyde group by simply folding the microdevice, which was heated at 65 °C for 5 min for colorimetric detection. An intense blue color was developed where the target DNA was present. These results indicate that the method proposed in this study is highly suitable for point-of-care applications, especially in resource-limited settings for the rapid detection of harmful pathogens. © 2023 American Chemical Society.

9.
Mikrochim Acta ; 190(4): 163, 2023 03 29.
Article in English | MEDLINE | ID: covidwho-2288591

ABSTRACT

Using rolling circle amplification (RCA) and two different ways of signal readout, we developed analytical methods to detect the receptor-binding domain (RBD) of SARS-CoV-2 spike protein (S protein). We modified streptavidin-coated magnetic beads with an aptamer of RBD through a biotin-tagged complementary DNA strand (biotin-cDNA). Binding of RBD caused the aptamer to dissociate from the biotin-cDNA, making the cDNA available to initiate RCA on the magnetic beads. Detection of RBD was achieved using a dual signal output. For fluorescence signaling, the RCA products were mixed with a dsDNA probe labeled with fluorophore and quencher. Hybridization of the RCA products caused the dsDNA to separate and to emit fluorescence (λex = 488 nm, λem = 520 nm). To generate easily detectable UV-vis absorbance signal, the RCA amplification was extended to produce DNA flower to encapsulate horseradish peroxidase (HRP). The HRP-encapsulated DNA flower catalyzed a colorimetric reaction between H2O2 and 3,3',5,5'-tetramethylbenzidine (TMB) to generate an optical signal (λabs = 450 nm). The fluorescence and colorimetric assays for RBD have low detection limits (0.11 pg mL-1 and 0.904 pg mL-1) and a wide linear range (0.001-100 ng mL-1). For detection of RBD in human saliva, the recovery was 93.0-100% for the fluorescence assay and 87.2-107% for the colorimetric assay. By combining fluorescence and colorimetric detection with RCA, detection of the target RBD in human saliva was achieved with high sensitivity and selectivity.


Subject(s)
COVID-19 , Fluorescent Dyes , Humans , SARS-CoV-2/genetics , SARS-CoV-2/metabolism , Biotin/chemistry , DNA, Complementary , Hydrogen Peroxide/chemistry , DNA/chemistry , Horseradish Peroxidase/metabolism
10.
ACS Appl Mater Interfaces ; 15(9): 12327-12338, 2023 Mar 08.
Article in English | MEDLINE | ID: covidwho-2287610

ABSTRACT

Timely, accurate, and rapid diagnosis of SARS-CoV-2 is a key factor in controlling the spread of the epidemic and guiding treatments. Herein, a flexible and ultrasensitive immunochromatographic assay (ICA) was proposed based on a colorimetric/fluorescent dual-signal enhancement strategy. We first fabricated a highly stable dual-signal nanocomposite (SADQD) by continuously coating one layer of 20 nm AuNPs and two layers of quantum dots onto a 200 nm SiO2 nanosphere to provide strong colorimetric signals and enhanced fluorescence signals. Two kinds of SADQD with red and green fluorescence were conjugated with spike (S) antibody and nucleocapsid (N) antibody, respectively, and used as dual-fluorescence/colorimetric tags for the simultaneous detection of S and N proteins on one test line of ICA strip, which can not only greatly reduce the background interference and improve the detection accuracy but also achieve a higher colorimetric sensitivity. The detection limits of the method for target antigens via colorimetric and fluorescence modes were as low as 50 and 2.2 pg/mL, respectively, which were 5 and 113 times more sensitive than those from the standard AuNP-ICA strips, respectively. This biosensor will provide a more accurate and convenient way to diagnose COVID-19 in different application scenarios.


Subject(s)
COVID-19 , Metal Nanoparticles , Humans , SARS-CoV-2 , COVID-19/diagnosis , Colorimetry/methods , Gold/chemistry , Silicon Dioxide , Metal Nanoparticles/chemistry , Coloring Agents , Antibodies , Immunoassay/methods
11.
Intervirology ; 65(4): 181-187, 2022.
Article in English | MEDLINE | ID: covidwho-2285612

ABSTRACT

INTRODUCTION: The ongoing spread of pandemic coronavirus disease-19 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is of growing concern. Rapid diagnosis and management of SARS-CoV-2 are crucial for controlling the outbreak in the community. Here, we report the development of a first rapid-colorimetric assay capable of detecting SARS-CoV-2 in the human nasopharyngeal RNA sample in less than 30 min. METHOD: We utilized a nanomaterial-based optical sensing platform to detect RNA-dependent RNA polymerase gene of SARS-CoV-2, where the formation of oligo probe-target hybrid led to salt-induced aggregation and change in gold-colloid color from pink to blue visibility range. Accordingly, we found a change in colloid color from pink to blue in assay containing nasopharyngeal RNA sample from the subject with clinically diagnosed COVID-19. The colloid retained pink color when the test includes samples from COVID-19 negative subjects or human papillomavirus-infected women. RESULTS: The results were validated using nasopharyngeal RNA samples from positive COVID-19 subjects (n = 136). Using real-time polymerase chain reaction as gold standard, the assay was found to have 85.29% sensitivity and 94.12% specificity. The optimized method has detection limit as little as 0.5 ng of SARS-CoV-2 RNA. CONCLUSION: We found that the developed assay rapidly detects SARS-CoV-2 RNA in clinical samples in a cost-effective manner and would be useful in pandemic management by facilitating mass screening.


Subject(s)
COVID-19 , SARS-CoV-2 , Female , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , RNA, Viral/genetics , RNA, Viral/analysis , Pandemics , RNA-Dependent RNA Polymerase , Sensitivity and Specificity
12.
Biointerface Research in Applied Chemistry ; 13(3), 2023.
Article in English | Scopus | ID: covidwho-2243783

ABSTRACT

Amplification of the RNA from the Covid-19 virus is considered the main objective of the molecular diagnosis of SARS-Cov-2. However, the use of target-based amplification methods such as polymerase chain reaction requires a step to convert the RNA of the Covid-19 virus into a DNA template to lead to amplification. In addition, isolating the RNA of the Covid-19 virus requires RNA purification kits, which will increase the time and costs of molecular detection of this virus. In this study, the magnetic nanoprobe is introduced that it could capture and amplify Covid-19 RNA through an isothermal amplification process called loop-mediated isothermal amplification without requiring a step to convert the viral RNA into a DNA template. By using the engineered sequences corresponding to the target nucleic acid attached to magnetic nanoparticles, it becomes possible to identify the target RNA of this virus through color changes due to pH changes that can be seen with the naked eye due to the presence of pH indicators in the reaction mix. According to the isothermal amplification of the viral RNA via LAMP assisted with the magnetic nanoprobe, the nanomolecular method eliminated the need for special equipment and the time for detecting Covid-19 in specimens. © 2022 by the authors.

13.
Talanta ; 252, 2023.
Article in English | Scopus | ID: covidwho-2243490

ABSTRACT

We developed a colorimetric analytical method for favipiravir (FPV), a promising treatment for COVID-19. FPV forms yellow complexes with ferrihydrite (Fh) by a ligand substitution reaction with the iron (III) hydroxyl surface groups in Fh. Fh-coated microbeads were packed into a capillary tube with an inner diameter of 1 mm. FPV-spiked serum after pretreatment was drawn into the capillary packed with Fh-coated microbeads. The intensities of the yellow-color complexes on the microbeads were transformed into red-green-blue (RGB) pixels using Image-J software 1.8, and the difference between green and blue was used as the analytical signal. The signal increased with increasing FPV concentration. The proposed method showed good linearity (R2 = 0.9907) over a concentration range of 25–200 μg/mL. The RSD (n = 3) and the LOD (3σ) values were estimated to be 2.8–15.4% and 16.91 μg/mL, respectively. The proposed method enables us to quantify FPV rapidly and easily without the need for expensive equipment. © 2022 Elsevier B.V.

14.
Biosensors (Basel) ; 13(1)2022 Dec 26.
Article in English | MEDLINE | ID: covidwho-2246528

ABSTRACT

Infectious pathogens cause severe threats to public health due to their frightening infectivity and lethal capacity. Rapid and accurate detection of pathogens is of great significance for preventing their infection. Gold nanoparticles have drawn considerable attention in colorimetric biosensing during the past decades due to their unique physicochemical properties. Colorimetric diagnosis platforms based on functionalized AuNPs are emerging as a promising pathogen-analysis technique with the merits of high sensitivity, low-cost, and easy operation. This review summarizes the recent development in this field. We first introduce the significance of detecting pathogens and the characteristics of gold nanoparticles. Four types of colorimetric strategies, including the application of indirect target-mediated aggregation, chromogenic substrate-mediated catalytic activity, point-of-care testing (POCT) devices, and machine learning-assisted colorimetric sensor arrays, are systematically introduced. In particular, three biomolecule-functionalized AuNP-based colorimetric sensors are described in detail. Finally, we conclude by presenting our subjective views on the present challenges and some appropriate suggestions for future research directions of colorimetric sensors.


Subject(s)
Biosensing Techniques , Metal Nanoparticles , Gold/chemistry , Metal Nanoparticles/chemistry , Colorimetry/methods , Biosensing Techniques/methods
15.
Small ; 19(20): e2208167, 2023 05.
Article in English | MEDLINE | ID: covidwho-2241393

ABSTRACT

Fluorescence-based PCR and other amplification methods have been used for SARS-CoV-2 diagnostics, however, it requires costly fluorescence detectors and probes limiting deploying large-scale screening. Here, a cut-price colorimetric method for SARS-CoV-2 RNA detection by iron manganese silicate nanozyme (IMSN) is established. IMSN catalyzes the oxidation of chromogenic substrates by its peroxidase (POD)-like activity, which is effectively inhibited by pyrophosphate ions (PPi). Due to the large number of PPi generated by amplification processes, SARS-CoV-2 RNA can be detected by a colorimetric readout visible to the naked eye, with the detection limit of 240 copies mL-1 . This conceptually new method has been successfully applied to correctly distinguish positive and negative oropharyngeal swab samples of COVID-19. Colorimetric assay provides a low-cost and instrumental-free solution for nucleic acid detection, which holds great potential for facilitating virus surveillance.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Colorimetry/methods , RNA, Viral/genetics , Nucleic Acid Amplification Techniques/methods
16.
Biosensors (Basel) ; 13(2)2023 Feb 15.
Article in English | MEDLINE | ID: covidwho-2238776

ABSTRACT

Even with the widespread uptake of vaccines, the SARS-CoV-2-induced COVID-19 pandemic continues to overwhelm many healthcare systems worldwide. Consequently, massive scale molecular diagnostic testing remains a key strategy to control the ongoing pandemic, and the need for instrument-free, economic and easy-to-use molecular diagnostic alternatives to PCR remains a goal of many healthcare providers, including WHO. We developed a test (Repvit) based on gold nanoparticles that can detect SARS-CoV-2 RNA directly from nasopharyngeal swab or saliva samples with a limit of detection (LOD) of 2.1 × 105 copies mL-1 by the naked eye (or 8 × 104 copies mL-1 by spectrophotometer) in less than 20 min, without the need for any instrumentation, and with a manufacturing price of <$1. We tested this technology on 1143 clinical samples from RNA extracted from nasopharyngeal swabs (n = 188), directly from saliva samples (n = 635; assayed by spectrophotometer) and nasopharyngeal swabs (n = 320) from multiple centers and obtained sensitivity values of 92.86%, 93.75% and 94.57% and specificities of 93.22%, 97.96% and 94.76%, respectively. To our knowledge, this is the first description of a colloidal nanoparticle assay that allows for rapid nucleic acid detection at clinically relevant sensitivity without the need for external instrumentation that could be used in resource-limited settings or for self-testing.


Subject(s)
COVID-19 , Metal Nanoparticles , Humans , Colorimetry , Saliva , RNA, Viral , SARS-CoV-2 , Gold , Pandemics , Nasopharynx , Specimen Handling
17.
Angew Chem Int Ed Engl ; 2022 Nov 21.
Article in English | MEDLINE | ID: covidwho-2241865

ABSTRACT

Aromatic interactions are commonly involved in the assembly of naturally occurring building blocks, and these interactions can be replicated in an artificial setting to produce functional materials. Here we describe a colorimetric biosensor using co-assembly experiments with plasmonic gold and surfactant-like peptides (SLPs) spanning a wide range of aromatic residues, polar stretches, and interfacial affinities. The SLPs programmed in DDD-(ZZ) x -FFPC self-assemble into higher-order structures in response to a protease and subsequently modulate the colloidal dispersity of gold leading to a colorimetric readout. Results show the strong aggregation propensity of the FFPC tail without polar DDD head. The SLPs were specific to the target protease, i.e., Mpro, a biomarker for SARS-CoV-2. This system is a simple and visual tool that senses Mpro in phosphate buffer, exhaled breath condensate, and saliva with detection limits of 15.7, 20.8, and 26.1 nM, respectively. These results may have value in designing other protease testing methods.

18.
ACS Sustainable Chemistry and Engineering ; 2022.
Article in English | Scopus | ID: covidwho-2235729

ABSTRACT

Here, we developed a copper sulfate (CuSO4)-initiated diphenylamine (DPA)-based colorimetric strategy coupled with loop-mediated isothermal amplification (LAMP) for rapid detection of two critical contagious pathogens, SARS-CoV-2 and Enterococcus faecium. To detect the DNA, acid hydrolysis of LAMP amplicons was executed, enabling the development of a blue color. In the LAMP amplicons, the bond between the purines and deoxyribose is extremely labile. It can be broken using 70% sulfuric acid followed by phosphate group elimination, which generates a highly active keto aldehyde group. CuSO4 plays an imperative role inducing DPA to rapidly react with the keto aldehyde group, producing an intense blue color within 5 min. Moreover, low quantities such as 103 copies μL-1 of SARS-CoV-2 RNA and 102 CFU mL-1 of E. faecium were successfully detected, revealing the advantages of the introduced method. To confirm practical applicability, multiplex detection of pathogens was performed using a foldable microdevice comprising reaction and detection zones. Various reactions such as DNA extraction, LAMP, and acid hydrolysis occurred in the reaction zone. Then, colorimetric reagents (DPA, CuSO4, and ethylene glycol) contained in the detection zone were mixed with the keto aldehyde group by simply folding the microdevice, which was heated at 65 °C for 5 min for colorimetric detection. An intense blue color was developed where the target DNA was present. These results indicate that the method proposed in this study is highly suitable for point-of-care applications, especially in resource-limited settings for the rapid detection of harmful pathogens. © 2023 American Chemical Society

19.
Talanta ; 256: 124271, 2023 May 01.
Article in English | MEDLINE | ID: covidwho-2183603

ABSTRACT

Rapid screening of multiple pathogens will greatly improve the efficiency of pandemic prevention and control. Colorimetric methods exhibit the advantages of convenience, portability, low cost, time efficiency, and free of sophisticated instruments, yet usually have difficulties in simultaneous detection and suffer from monotonous color changes with low visual resolution and sensitivity. Hence, coupled three kinds of plasmonic nanoparticles (NPs) with magnetic separation, we developed an achromatic colorimetric nanosensor with highly enhanced visual resolution for simultaneous detection of SARS-CoV-2, Staphylococcus aureus, and Salmonella typhimurium. The achromatic nanosensor was composed of SARS-CoV-2-targeting red gold NPs, S. aureus-targeting yellow silver NPs and S. typhimurium-targeting blue silver triangle NPs mixed as black color. In the detection, three corresponding magnetic probes were added into the above mixture. In the presence of a target pathogen, it would be recognized and combined with corresponding colored reporters and magnetic probes to form sandwich complexes, which were removed by magnetic separation, and the sensor changed from black to a chromatic color (the color of the reporters remained in supernatant). Consequently, different target pathogen induced different color. For example, SARS-CoV-2, S. aureus, and S. typhimurium respectively produced green, purple, and orange. While coexistence of S. aureus and S. typhimurium produced red, and coexistence of S. aureus and SARS-CoV-2 produced blue, etc. Therefore, by observing the color change or measuring the absorption spectra, multiple pathogen detection was achieved conveniently. Compared with most colorimetric sensors, this achromatic nanosensor involved rich color change, thus significantly enhancing visual resolution and inspection sensitivity. Therefore, this sensor opened a promising avenue for efficient monitoring and early warning of food safety and quality.


Subject(s)
COVID-19 , Metal Nanoparticles , Nanoparticles , Humans , Silver , Colorimetry/methods , Staphylococcus aureus , COVID-19/diagnosis , SARS-CoV-2 , Gold , Magnetic Phenomena
20.
MethodsX ; 10: 102011, 2023.
Article in English | MEDLINE | ID: covidwho-2181610

ABSTRACT

SARS-CoV-2 is a public pandemic health concern globally. Nasopharyngeal and oropharyngeal swab samples are used for Covid-19 viral detection. Sample collection procedure was tedious and uncomfortable and unsuitable for biochemical and CBC analysis in swab samples. Biochemistry and CBC tests are key determinant in management of Covid-19 patients. We developed a LAMP test to detect viral RNA in blood samples. LAMP is required four specific primers targeting the internal transcribed S-region and loop primers for viral RNA amplification. RNA was extracted from blood samples by TRIzol method. LAMP reaction was performed at 60 °C for 1 hour and amplicons were visualized in HNB dye. No cross-reactivity was seen with HBV, HCV, and HIV infected sample. Out of 40 blood samples, 33 samples were positive for LAMP and Q-PCR analysis, one sample was positive for LAMP and negative for Q-PCR, two samples were negative for LAMP but positive for Q-PCR, and four blood samples were negative for LAMP and Q-PCR. LAMP method has an accuracy of 92.50%, with sensitivity and specificity of 94.28% and 80%, respectively. Thus, LAMP diagnostic test has proved reliable, fast, inexpensive and can be useful for detection where the limited resources available.•LAMP method is a potential tool for detection of SARS-CoV-2.•Blood samples are the key determinant for routine diagnostics as well as molecular diagnostics.•LAMP assay is an appropriate diagnostics method which offers greater simplicity, low cost, sensitivity, and specificity than other methods in molecular diagnostics.

SELECTION OF CITATIONS
SEARCH DETAIL